ICM Controls ICM2909 Rheem DSI 62-23599-02 replacement
Rheem OEM Replacement Control
Direct Spark Ignition (DSI) Control Board
The ICM2909 DSI control replaces the following Rheem models: 62-23599(-01,-02,-03,-04,-05). The ICM2909 has incorporated LED diagnostics to assist in troubleshooting. Fault code information can be found in the application guide.
DETAILS:
Rheem Replacement (DSI) control board
- Direct Spark Ignition (DSI) control board
- Microprocessor-based
- Monitors timing, trial for ignition, system switches, flame sensing and lockout
- 100% lockout safety feature
- Compatible with LP or Natural Gas
- LED indication for status and fault codes to aid in troubleshooting
SPECIFICATIONS:
¦ Inputs
- Line voltage: 208-230 VAC, 50/60 Hz
- Control voltage: 18-30 VAC, 50/60 Hz
- System switches: Vent pressure, limit and MRLC (Manual Reset Limit Control)
¦ Outputs
- Heat N.C.: 16FLA/30 LRA @ 277 VAC, 30K @ 85°C
- Cool N.O.: 15FLA/36 LRA @ 277 VAC, 100K @ 85°C
- Inducer: 9.8FLA/58.8LRA, 1/2HP @ 120 VAC, 6K @ 75°C
- Gas valve: 2.3 A PILOT DUTY @ 240 VAC, 6K @ 75°C
¦ Heat Operation Timing
- Pre-purge: 3 seconds
- Heat blower ON delay: 30 seconds
- Post-purge: 5 seconds
- Heat blower OFF delay: 90 seconds
- Ignition trial: 7 seconds
- Inter-purge (retrial): 15 seconds
- Ignition activation period: 5 seconds
- Flame establishing period: 2 seconds
- Flame failure response time: 0.8 seconds (maximum)
¦ Cooling Operation
- Cool blower On delay: 1 second
- Cool blower Off delay: 30 seconds
¦ Lockout Timing
- Auto reset lockout: 60 minutes
¦ Environmental
- Operating temperature: -40°F to 175°F (-40°C to 80°C)
- Storage temperature: -40°F to 185°F (-40°C to 85°C)
- Humidity: 5% Â 95% R.H. (non-condensing) at +55°C
WEIGHT/DIMENSIONS:
Height: 2.25
Width: 6.60
Length: 5.75